TimeWaver Accessories

Grid  List 

PALS Blue high quality electrode

PALS Blue electrode -  specialized gel gentle enough for sensitive skin

PALS® Blue
Designed for all FES and TENS applications, PALS® Blue neurostimulation electrodes combine a patented stainless steel knit cloth and hydrogel construction with our exclusive impedance compensation system. The stainless steel fabric provides optimum conductivity and conformity while the specialized gel is thick enough to adhere through body hair yet gentle enough for use on extremely sensitive skin.

Key Benefits:

  • Specially formulated electrodes
  • Designed for sensitive skin and delicate areas
  • Thick gentle gel
  • Remove easily from skin and do not pull on body hair when removed
  • Designed for all FES and TENS applications
  • Patented stainless steel knit cloth and hydrogel construction
  • Gentle enough for use on extremely sensitive skin
  • Axelgaard PALS Platinum Blue Neurostimulation Electrodes combine a patented stainless steel knit cloth and hydrogel construction
  • Patented stainless steel fabric for optimum conductivity and conformity
  • Gel for extremely sensitive skin
  • Perfect for sensitive skin and hard to treat areas
  • Adheres through body hair
  • Enhance patient comfort during stimulation
  • Disperse current evenly across the electrode
  • Eliminate stinging, edge biting and hot spots
  • Self-adhering and reusable electrodes

 

Learn More

UltraStim X Blue square (5*5cm)

UltraStim® X Blue square -  then new ultra thin electrode for sensitive skin

UltraStim® X Blue
The NEW UltraStim® X BLUE electrodes that feature a BLUE Hydrogel for those with extremely sensitive skin are the next evolution of the superior UltraStim® X design. The distinctive silver grid pattern on UltraStim® X BLUE electrodes provides even current dispersion, which translates into a more comfortable therapy treatment for the user. The oversized border is specially designed to facilitate ease of proper removal to further promote electrode durability. Users can now experience the same exceptional quality and value of Axelgaard’s unique cutting-edge technology and manufacturing process for UltraStim® X with BLUE Hydrogel for sensitive skin with a water repellent backing.

Designed to provide professional-grade electrical stimulation for pain relief purposes in personal or professional environments
Made of the same cutting-edge technology as the traditional UltraStim X but with BLUE Hydrogel for sensitive skin
Features a 3-layer design that includes a water repellent backing, conductive film, and hydrogel adhesive

Blue Hydrogel
The newly design UltraStim X Blue electrodes feature Blue Hydrogel. Blue Hydrogel is an adhesive backing that is especially designed for those with sensitive skin. UltraStim X features an original silver grid pattern that provides even electric current dispersion. This technology provides a more comfortable therapy treatment for your patient. The oversized border is used to aid in proper removal to extend electrode life.

Unique Design
UltraStim X Blue electrodes feature a unique 3-layer design. The top layer is a water-repellent fabric that prolongs the electrodes use and life. The second layer is a conductive film printed layer with a patented silver grid. The final layer is a hydrogel formulated patch that is designed specifically for those with sensitive skin.

 

Learn More

UltraStim Snap (square 5*5cm)

UltraStim® Snap -  "button" electrode for sensitive skin

UltraStim® Snap patented current controlling neurostimulation electrodes distribute current as evenly and comfortably as the UltraStim® Wire product line through the use of a snap connector rather than a lead wire. The bottom snap is scientifically chosen to match impedance in the entire system to provide even current distribution across the surface, even with a snap. The proprietary silver grid pattern is specially calculated to precisely control electrical current over the electrode surface, while the border around the grid pattern allows for an intentional current roll off to eliminate edge stinging. Utilizing Axelgaard’s patented multi-layer MultiStick® hydrogel eliminates performance problems associated with electrodes featuring single-layer gels.UltraStim® X Blue
The NEW UltraStim® X BLUE electrodes that feature a BLUE Hydrogel for those with extremely sensitive skin are the next evolution of the superior UltraStim® X design. The distinctive silver grid pattern on UltraStim® X BLUE electrodes provides even current dispersion, which translates into a more comfortable therapy treatment for the user. The oversized border is specially designed to facilitate ease of proper removal to further promote electrode durability. Users can now experience the same exceptional quality and value of Axelgaard’s unique cutting-edge technology and manufacturing process for UltraStim® X with BLUE Hydrogel for sensitive skin with a water repellent backing.

 

The newly design UltraStim X Blue electrodes feature Blue Hydrogel. Blue Hydrogel is an adhesive backing that is especially designed for those with sensitive skin. UltraStim X features an original silver grid pattern that provides even electric current dispersion. This technology provides a more comfortable therapy treatment for your patient. The oversized border is used to aid in proper removal to extend electrode life.

Unique Design
UltraStim X Blue electrodes feature a unique 3-layer design. The top layer is a water-repellent fabric that prolongs the electrodes use and life. The second layer is a conductive film printed layer with a patented silver grid. The final layer is a hydrogel formulated patch that is designed specifically for those with sensitive skin.

 

Learn More

SIS ELECTROTHERAPY ELECTRODES LARGE

Delivery time for pre-orders are normally from 3-10 days

SIS ELECTROTHERAPY ELECTRODES 
SIS 10cm×15cm (4×6 inch) large rectangular silver plated electrodes (4 in each package)


Unique SIS Electrode Features

  • Far higher electrical conductivity (5-400×, typical 100×) than standard electrotherapy electrodes:
  • Total bioelectrical circuit resistance on intact skin below 50 kiloOhms as standard and below 10 kiloOhms normally achievable.
  • Electrodes are applied with tap water and standard fixation tape.
  • SIS electrodes can conduct lower intensity and higher precision stimulation direct Output Currents and frequency based stimulation, using far lower voltages.
  • Optimal for extended applications.
  • Improved skin protection; electrodes can also be used over standard wet gauze.
  • Originally designed to meet the requirements and appropriate for high precision surface wound stimulation.

Further information
Typical self-adhesive hydrogel electrodes placed in contact with intact skin typically contribute between 1-2 and up to 4 megaOhms (4,000,000) of electrical resistance per pair. SIS electrodes typically contribute only 20-50 kiloOhms (50,000) under the same conditions.

Translated to clinical application, this means that to deliver 10 microAmperes of electric current (microcurrent) into the body with hydrogel electrodes would need 20 volts, which would damage skin and cells. In reality, with a lower applied stimulation voltage, that much current never conducts through the body. Using the SIS electrodes, only 0.2-0.5 volts would be needed to conduct the same microcurrent.

Learn More

SIS ELECTROTHERAPY ELECTRODES round

Delivery time for pre-orders are normally from 3-10 days

SIS ELECTROTHERAPY ELECTRODES round (4 pack)
SIS 4.7cm (1.87 inch) diameter circular silver-nylon active stimulation area. Excellent for Cranial Electrical Stimulation (CES), accupuncture points or general electrostimulation therapy. Provides silver ions for antibacterial effects. 


Unique SIS Electrode Features

  • Far higher electrical conductivity (5-400×, typical 100×) than standard electrotherapy electrodes:
  • Total bioelectrical circuit resistance on intact skin below 50 kiloOhms as standard and below 10 kiloOhms normally achievable.
  • Electrodes are applied with tap water and standard fixation tape.
  • SIS electrodes can conduct lower intensity and higher precision stimulation direct Output Currents and frequency based stimulation, using far lower voltages.
  • Optimal for extended applications.
  • Improved skin protection; electrodes can also be used over standard wet gauze.
  • Originally designed to meet the requirements and appropriate for high precision surface wound stimulation.

Further information
Typical self-adhesive hydrogel electrodes placed in contact with intact skin typically contribute between 1-2 and up to 4 megaOhms (4,000,000) of electrical resistance per pair. SIS electrodes typically contribute only 20-50 kiloOhms (50,000) under the same conditions.

Translated to clinical application, this means that to deliver 10 microAmperes of electric current (microcurrent) into the body with hydrogel electrodes would need 20 volts, which would damage skin and cells. In reality, with a lower applied stimulation voltage, that much current never conducts through the body. Using the SIS electrodes, only 0.2-0.5 volts would be needed to conduct the same microcurrent.

Learn More

Grid  List